Civil Engineering · Steel Structures

Unit 2: Tension Members MCQs

50 solved multiple choice questions with answers and short explanations.

Q1. A concentrically loaded steel tension member is primarily subjected to what?

  1. APure compression
  2. BPure torsion only
  3. CAxial tensile force
  4. DHydrostatic pressure
Show answer
Answer: C. Axial tensile forceA tension member primarily transfers axial tensile force.
Report a mistake

Q2. Which behavior is generally desirable before tensile fracture?

  1. ASudden brittle failure
  2. BImmediate buckling
  3. CLoss of all connection force
  4. DDuctile yielding
Show answer
Answer: D. Ductile yieldingDuctile yielding provides deformation and warning before fracture.
Report a mistake

Q3. Why can a tension member fail at a connection even if its gross section is adequate?

  1. ABolt holes or connection geometry can reduce the effective net section
  2. BConnections increase every section area
  3. CBolt holes add material
  4. DConnections eliminate stress
Show answer
Answer: A. Bolt holes or connection geometry can reduce the effective net sectionConnection holes and shear lag can reduce effective tensile resistance.
Report a mistake

Q4. Which quantity is used for gross-section yielding checks?

  1. ANet area only
  2. BGross cross-sectional area
  3. CBolt head area
  4. DWeld electrode area
Show answer
Answer: B. Gross cross-sectional areaGross-section yielding is based on the unreduced member area.
Report a mistake

Q5. Which quantity is central to fracture checks through a line of holes?

  1. AGross volume only
  2. BPaint thickness
  3. CNet or effective net area
  4. DMember length only
Show answer
Answer: C. Net or effective net areaFracture through a perforated section depends on the remaining effective net area.
Report a mistake

Q6. What is the main purpose of studying Tension Member Behavior in steel-structure design?

  1. ATo determine land-survey coordinates only
  2. BTo eliminate the need for structural analysis
  3. CTo select architectural finishes only
  4. DTo evaluate the structural behavior and design requirements associated with Tension Member Behavior
Show answer
Answer: D. To evaluate the structural behavior and design requirements associated with Tension Member BehaviorTension Member Behavior is studied to understand relevant behavior, limit states, resistance, stability, and detailing requirements.
Report a mistake

Q7. When beginning a design check for Tension Member Behavior, which information is most important to establish?

  1. AActions, geometry, material properties, restraints, and design assumptions
  2. BPaint color and drawing border
  3. COnly the member name
  4. DOnly the final connection sketch
Show answer
Answer: A. Actions, geometry, material properties, restraints, and design assumptionsA reliable Tension Member Behavior check starts with loads/actions, geometry, material properties, boundary conditions, restraints, and assumptions.
Report a mistake

Q8. Which statement represents good engineering practice for Tension Member Behavior?

  1. ACheck only member self-weight
  2. BCheck all relevant strength, stability, serviceability, and detailing requirements
  3. CIgnore connection behavior
  4. DAssume every member is perfectly rigid
Show answer
Answer: B. Check all relevant strength, stability, serviceability, and detailing requirementsSteel design for Tension Member Behavior should consider all applicable limit states and detailing provisions.
Report a mistake

Q9. Why is the governing design standard important when evaluating Tension Member Behavior?

  1. ASteel properties change with the language of the code
  2. BAll standards use identical coefficients
  3. CDesign equations, factors, limits, and detailing rules can differ among standards
  4. DCodes apply only to drawing presentation
Show answer
Answer: C. Design equations, factors, limits, and detailing rules can differ among standardsThe adopted standard defines the design format and provisions applicable to Tension Member Behavior.
Report a mistake

Q10. What should an engineer do if a design check for Tension Member Behavior is not satisfied?

  1. AIgnore the failed check
  2. BDelete the calculation
  3. CKeep the design unchanged
  4. DRevise the member, connection, restraint, or structural arrangement and recheck
Show answer
Answer: D. Revise the member, connection, restraint, or structural arrangement and recheckA failed Tension Member Behavior check requires an appropriate design revision followed by verification.
Report a mistake

Q11. What is the main purpose of studying Gross & Net Section in steel-structure design?

  1. ATo evaluate the structural behavior and design requirements associated with Gross & Net Section
  2. BTo determine land-survey coordinates only
  3. CTo eliminate the need for structural analysis
  4. DTo select architectural finishes only
Show answer
Answer: A. To evaluate the structural behavior and design requirements associated with Gross & Net SectionGross & Net Section is studied to understand relevant behavior, limit states, resistance, stability, and detailing requirements.
Report a mistake

Q12. When beginning a design check for Gross & Net Section, which information is most important to establish?

  1. APaint color and drawing border
  2. BActions, geometry, material properties, restraints, and design assumptions
  3. COnly the member name
  4. DOnly the final connection sketch
Show answer
Answer: B. Actions, geometry, material properties, restraints, and design assumptionsA reliable Gross & Net Section check starts with loads/actions, geometry, material properties, boundary conditions, restraints, and assumptions.
Report a mistake

Q13. Which statement represents good engineering practice for Gross & Net Section?

  1. ACheck only member self-weight
  2. BIgnore connection behavior
  3. CCheck all relevant strength, stability, serviceability, and detailing requirements
  4. DAssume every member is perfectly rigid
Show answer
Answer: C. Check all relevant strength, stability, serviceability, and detailing requirementsSteel design for Gross & Net Section should consider all applicable limit states and detailing provisions.
Report a mistake

Q14. Why is the governing design standard important when evaluating Gross & Net Section?

  1. ASteel properties change with the language of the code
  2. BAll standards use identical coefficients
  3. CCodes apply only to drawing presentation
  4. DDesign equations, factors, limits, and detailing rules can differ among standards
Show answer
Answer: D. Design equations, factors, limits, and detailing rules can differ among standardsThe adopted standard defines the design format and provisions applicable to Gross & Net Section.
Report a mistake

Q15. What should an engineer do if a design check for Gross & Net Section is not satisfied?

  1. ARevise the member, connection, restraint, or structural arrangement and recheck
  2. BIgnore the failed check
  3. CDelete the calculation
  4. DKeep the design unchanged
Show answer
Answer: A. Revise the member, connection, restraint, or structural arrangement and recheckA failed Gross & Net Section check requires an appropriate design revision followed by verification.
Report a mistake

Q16. Why should units be kept consistent in calculations involving Gross & Net Section?

  1. AUnits affect only spreadsheet appearance
  2. BTo obtain physically meaningful and numerically correct results
  3. CAny units may be mixed without conversion
  4. DUnits are irrelevant in structural equations
Show answer
Answer: B. To obtain physically meaningful and numerically correct resultsConsistent units are essential for reliable calculations involving Gross & Net Section.
Report a mistake

Q17. Which item should be documented in a calculation for Gross & Net Section?

  1. AOnly the final numerical answer
  2. BUnrelated personal notes
  3. CKey assumptions, inputs, governing criteria, and results
  4. DOnly the drawing title
Show answer
Answer: C. Key assumptions, inputs, governing criteria, and resultsDocumenting assumptions and governing criteria makes a Gross & Net Section calculation reviewable and auditable.
Report a mistake

Q18. Why can detailing influence the actual performance of Gross & Net Section?

  1. ABecause detailing removes all applied loads
  2. BBecause drawings change steel yield strength
  3. CBecause detailing eliminates deformation
  4. DBecause force transfer, stability, fit-up, and constructability depend on the physical details
Show answer
Answer: D. Because force transfer, stability, fit-up, and constructability depend on the physical detailsActual structural behavior depends on how members and connections are physically detailed and constructed.
Report a mistake

Q19. What is the safest general approach when more than one limit state may affect Gross & Net Section?

  1. AEvaluate each relevant limit state and design for the governing requirement
  2. BChoose the easiest equation only
  3. CCheck one limit state at random
  4. DAssume the largest member always passes
Show answer
Answer: A. Evaluate each relevant limit state and design for the governing requirementMultiple failure or service modes can govern Gross & Net Section, so each applicable limit state should be evaluated.
Report a mistake

Q20. What does a satisfactory design outcome for Gross & Net Section generally mean?

  1. AThe member has the maximum possible weight
  2. BDesign demand is within applicable resistance and performance limits
  3. CNo deformation occurs under any load
  4. DNo engineering judgment is required
Show answer
Answer: B. Design demand is within applicable resistance and performance limitsA satisfactory Gross & Net Section design meets applicable resistance, stability, serviceability, and detailing criteria.
Report a mistake

Q21. Block shear failure occurs primarily near what?

  1. AMidspan of an unconnected beam only
  2. BConcrete footing center
  3. CA connected end of a tension member
  4. DRoof membrane
Show answer
Answer: C. A connected end of a tension memberBlock shear is a connection-region limit state involving a block of material around fasteners.
Report a mistake

Q22. Block shear combines which types of failure surfaces?

  1. ACompression and torsion only
  2. BBending and thermal expansion
  3. CCorrosion and fatigue only
  4. DShear and tension
Show answer
Answer: D. Shear and tensionA block can tear out through shear planes plus a transverse tension plane.
Report a mistake

Q23. Why is bolt layout relevant to block shear?

  1. AIt defines potential shear and tension failure paths
  2. BBolt layout changes steel modulus
  3. CIt eliminates net area
  4. DIt determines paint thickness
Show answer
Answer: A. It defines potential shear and tension failure pathsFastener spacing and edge distances affect the geometry of possible block-shear paths.
Report a mistake

Q24. Block shear is checked in addition to what other tension-member limit states?

  1. AConcrete punching only
  2. BGross yielding and net-section fracture
  3. CBeam deflection only
  4. DSoil bearing only
Show answer
Answer: B. Gross yielding and net-section fractureTension members can be governed by several distinct limit states.
Report a mistake

Q25. What is the physical result of a block shear failure?

  1. AThe entire member melts
  2. BThe beam becomes perfectly rigid
  3. CA block of material tears out around the connection
  4. DThe bolts add section area
Show answer
Answer: C. A block of material tears out around the connectionThe combined shear and tension paths isolate and tear out a block near the connection.
Report a mistake

Q26. What is the main purpose of studying Block Shear in steel-structure design?

  1. ATo determine land-survey coordinates only
  2. BTo eliminate the need for structural analysis
  3. CTo select architectural finishes only
  4. DTo evaluate the structural behavior and design requirements associated with Block Shear
Show answer
Answer: D. To evaluate the structural behavior and design requirements associated with Block ShearBlock Shear is studied to understand relevant behavior, limit states, resistance, stability, and detailing requirements.
Report a mistake

Q27. When beginning a design check for Block Shear, which information is most important to establish?

  1. AActions, geometry, material properties, restraints, and design assumptions
  2. BPaint color and drawing border
  3. COnly the member name
  4. DOnly the final connection sketch
Show answer
Answer: A. Actions, geometry, material properties, restraints, and design assumptionsA reliable Block Shear check starts with loads/actions, geometry, material properties, boundary conditions, restraints, and assumptions.
Report a mistake

Q28. Which statement represents good engineering practice for Block Shear?

  1. ACheck only member self-weight
  2. BCheck all relevant strength, stability, serviceability, and detailing requirements
  3. CIgnore connection behavior
  4. DAssume every member is perfectly rigid
Show answer
Answer: B. Check all relevant strength, stability, serviceability, and detailing requirementsSteel design for Block Shear should consider all applicable limit states and detailing provisions.
Report a mistake

Q29. Why is the governing design standard important when evaluating Block Shear?

  1. ASteel properties change with the language of the code
  2. BAll standards use identical coefficients
  3. CDesign equations, factors, limits, and detailing rules can differ among standards
  4. DCodes apply only to drawing presentation
Show answer
Answer: C. Design equations, factors, limits, and detailing rules can differ among standardsThe adopted standard defines the design format and provisions applicable to Block Shear.
Report a mistake

Q30. What should an engineer do if a design check for Block Shear is not satisfied?

  1. AIgnore the failed check
  2. BDelete the calculation
  3. CKeep the design unchanged
  4. DRevise the member, connection, restraint, or structural arrangement and recheck
Show answer
Answer: D. Revise the member, connection, restraint, or structural arrangement and recheckA failed Block Shear check requires an appropriate design revision followed by verification.
Report a mistake

Q31. What is the main purpose of studying Effective Net Area in steel-structure design?

  1. ATo evaluate the structural behavior and design requirements associated with Effective Net Area
  2. BTo determine land-survey coordinates only
  3. CTo eliminate the need for structural analysis
  4. DTo select architectural finishes only
Show answer
Answer: A. To evaluate the structural behavior and design requirements associated with Effective Net AreaEffective Net Area is studied to understand relevant behavior, limit states, resistance, stability, and detailing requirements.
Report a mistake

Q32. When beginning a design check for Effective Net Area, which information is most important to establish?

  1. APaint color and drawing border
  2. BActions, geometry, material properties, restraints, and design assumptions
  3. COnly the member name
  4. DOnly the final connection sketch
Show answer
Answer: B. Actions, geometry, material properties, restraints, and design assumptionsA reliable Effective Net Area check starts with loads/actions, geometry, material properties, boundary conditions, restraints, and assumptions.
Report a mistake

Q33. Which statement represents good engineering practice for Effective Net Area?

  1. ACheck only member self-weight
  2. BIgnore connection behavior
  3. CCheck all relevant strength, stability, serviceability, and detailing requirements
  4. DAssume every member is perfectly rigid
Show answer
Answer: C. Check all relevant strength, stability, serviceability, and detailing requirementsSteel design for Effective Net Area should consider all applicable limit states and detailing provisions.
Report a mistake

Q34. Why is the governing design standard important when evaluating Effective Net Area?

  1. ASteel properties change with the language of the code
  2. BAll standards use identical coefficients
  3. CCodes apply only to drawing presentation
  4. DDesign equations, factors, limits, and detailing rules can differ among standards
Show answer
Answer: D. Design equations, factors, limits, and detailing rules can differ among standardsThe adopted standard defines the design format and provisions applicable to Effective Net Area.
Report a mistake

Q35. What should an engineer do if a design check for Effective Net Area is not satisfied?

  1. ARevise the member, connection, restraint, or structural arrangement and recheck
  2. BIgnore the failed check
  3. CDelete the calculation
  4. DKeep the design unchanged
Show answer
Answer: A. Revise the member, connection, restraint, or structural arrangement and recheckA failed Effective Net Area check requires an appropriate design revision followed by verification.
Report a mistake

Q36. Why should units be kept consistent in calculations involving Effective Net Area?

  1. AUnits affect only spreadsheet appearance
  2. BTo obtain physically meaningful and numerically correct results
  3. CAny units may be mixed without conversion
  4. DUnits are irrelevant in structural equations
Show answer
Answer: B. To obtain physically meaningful and numerically correct resultsConsistent units are essential for reliable calculations involving Effective Net Area.
Report a mistake

Q37. Which item should be documented in a calculation for Effective Net Area?

  1. AOnly the final numerical answer
  2. BUnrelated personal notes
  3. CKey assumptions, inputs, governing criteria, and results
  4. DOnly the drawing title
Show answer
Answer: C. Key assumptions, inputs, governing criteria, and resultsDocumenting assumptions and governing criteria makes a Effective Net Area calculation reviewable and auditable.
Report a mistake

Q38. Why can detailing influence the actual performance of Effective Net Area?

  1. ABecause detailing removes all applied loads
  2. BBecause drawings change steel yield strength
  3. CBecause detailing eliminates deformation
  4. DBecause force transfer, stability, fit-up, and constructability depend on the physical details
Show answer
Answer: D. Because force transfer, stability, fit-up, and constructability depend on the physical detailsActual structural behavior depends on how members and connections are physically detailed and constructed.
Report a mistake

Q39. What is the safest general approach when more than one limit state may affect Effective Net Area?

  1. AEvaluate each relevant limit state and design for the governing requirement
  2. BChoose the easiest equation only
  3. CCheck one limit state at random
  4. DAssume the largest member always passes
Show answer
Answer: A. Evaluate each relevant limit state and design for the governing requirementMultiple failure or service modes can govern Effective Net Area, so each applicable limit state should be evaluated.
Report a mistake

Q40. What does a satisfactory design outcome for Effective Net Area generally mean?

  1. AThe member has the maximum possible weight
  2. BDesign demand is within applicable resistance and performance limits
  3. CNo deformation occurs under any load
  4. DNo engineering judgment is required
Show answer
Answer: B. Design demand is within applicable resistance and performance limitsA satisfactory Effective Net Area design meets applicable resistance, stability, serviceability, and detailing criteria.
Report a mistake

Q41. What is the main purpose of studying Tension Member Design in steel-structure design?

  1. ATo determine land-survey coordinates only
  2. BTo eliminate the need for structural analysis
  3. CTo evaluate the structural behavior and design requirements associated with Tension Member Design
  4. DTo select architectural finishes only
Show answer
Answer: C. To evaluate the structural behavior and design requirements associated with Tension Member DesignTension Member Design is studied to understand relevant behavior, limit states, resistance, stability, and detailing requirements.
Report a mistake

Q42. When beginning a design check for Tension Member Design, which information is most important to establish?

  1. APaint color and drawing border
  2. BOnly the member name
  3. COnly the final connection sketch
  4. DActions, geometry, material properties, restraints, and design assumptions
Show answer
Answer: D. Actions, geometry, material properties, restraints, and design assumptionsA reliable Tension Member Design check starts with loads/actions, geometry, material properties, boundary conditions, restraints, and assumptions.
Report a mistake

Q43. Which statement represents good engineering practice for Tension Member Design?

  1. ACheck all relevant strength, stability, serviceability, and detailing requirements
  2. BCheck only member self-weight
  3. CIgnore connection behavior
  4. DAssume every member is perfectly rigid
Show answer
Answer: A. Check all relevant strength, stability, serviceability, and detailing requirementsSteel design for Tension Member Design should consider all applicable limit states and detailing provisions.
Report a mistake

Q44. Why is the governing design standard important when evaluating Tension Member Design?

  1. ASteel properties change with the language of the code
  2. BDesign equations, factors, limits, and detailing rules can differ among standards
  3. CAll standards use identical coefficients
  4. DCodes apply only to drawing presentation
Show answer
Answer: B. Design equations, factors, limits, and detailing rules can differ among standardsThe adopted standard defines the design format and provisions applicable to Tension Member Design.
Report a mistake

Q45. What should an engineer do if a design check for Tension Member Design is not satisfied?

  1. AIgnore the failed check
  2. BDelete the calculation
  3. CRevise the member, connection, restraint, or structural arrangement and recheck
  4. DKeep the design unchanged
Show answer
Answer: C. Revise the member, connection, restraint, or structural arrangement and recheckA failed Tension Member Design check requires an appropriate design revision followed by verification.
Report a mistake

Q46. Why should units be kept consistent in calculations involving Tension Member Design?

  1. AUnits affect only spreadsheet appearance
  2. BAny units may be mixed without conversion
  3. CUnits are irrelevant in structural equations
  4. DTo obtain physically meaningful and numerically correct results
Show answer
Answer: D. To obtain physically meaningful and numerically correct resultsConsistent units are essential for reliable calculations involving Tension Member Design.
Report a mistake

Q47. Which item should be documented in a calculation for Tension Member Design?

  1. AKey assumptions, inputs, governing criteria, and results
  2. BOnly the final numerical answer
  3. CUnrelated personal notes
  4. DOnly the drawing title
Show answer
Answer: A. Key assumptions, inputs, governing criteria, and resultsDocumenting assumptions and governing criteria makes a Tension Member Design calculation reviewable and auditable.
Report a mistake

Q48. Why can detailing influence the actual performance of Tension Member Design?

  1. ABecause detailing removes all applied loads
  2. BBecause force transfer, stability, fit-up, and constructability depend on the physical details
  3. CBecause drawings change steel yield strength
  4. DBecause detailing eliminates deformation
Show answer
Answer: B. Because force transfer, stability, fit-up, and constructability depend on the physical detailsActual structural behavior depends on how members and connections are physically detailed and constructed.
Report a mistake

Q49. What is the safest general approach when more than one limit state may affect Tension Member Design?

  1. AChoose the easiest equation only
  2. BCheck one limit state at random
  3. CEvaluate each relevant limit state and design for the governing requirement
  4. DAssume the largest member always passes
Show answer
Answer: C. Evaluate each relevant limit state and design for the governing requirementMultiple failure or service modes can govern Tension Member Design, so each applicable limit state should be evaluated.
Report a mistake

Q50. What does a satisfactory design outcome for Tension Member Design generally mean?

  1. AThe member has the maximum possible weight
  2. BNo deformation occurs under any load
  3. CNo engineering judgment is required
  4. DDesign demand is within applicable resistance and performance limits
Show answer
Answer: D. Design demand is within applicable resistance and performance limitsA satisfactory Tension Member Design design meets applicable resistance, stability, serviceability, and detailing criteria.
Report a mistake